澳门大金沙

Home > Product & Solution > PV products
Name of commodity: Refrigerator frequency converter inverter board
Commodity Numbers:403
Shelves time: 2014/9/5 14:28:52
Views:443

  

Detailed

Two big "advantage" 

Energy-saving advantages: the use of frequency converter technology is mainly run from the refrigerator, use energy-saving, by changing the compressor speed to change the cooling capacity of the refrigerator, so that the cooling capacity can be based on the ambient temperature and load change, thereby reducing downtime open and reduce power consumption. Meanwhile, a refrigerator used in the DC speed compressor and reduces the excitation losses compressor motor, compressor efficiency is further improved. 

 

Noise reduction advantages: compressor uses a brushless DC motors, three-phase stator windings, rotor pole permanent magnet excitation using without excitation coils, energy saving, no heat, by increasing the magnetic pole arc coefficient (ie increasing magnetic pole arc ), poly axial magnetic rotor overall magnetization and other measures to significantly improve the air-gap flux density of the motor to increase output, its starting torque up to 3.5 times the rated torque, so starting torque brushless DC motor much larger than the traditional single-phase asynchronous motors, compressors ensures quick start, smooth operation. 

Four "Features" 

Overvoltage, undervoltage, overcurrent protection function ; 

Compressor stall protection; 

Automatic recovery function; 

Compressor three minutes delay protection function 

 

Common technical parameters: 

 

Model 

DSP-001-HXN 

Supply voltage range

165V ~ 275V 

AC input voltage frequency

47 ~ 63HZ

Controller Operating ambient temperature range

 (0 ~ + 45) ℃ 

Controller Operating humidity range 

20% ~ 90%

The maximum output power

300W 

Speed ​​range 

1600 ~ 4200rpm 

Corresponds to the control frequency

54Hz-140Hz 

1) When the input frequency <50Hz 

2) When the input frequency between 50-54Hz 

3) When the input frequency between 54-140Hz 

4) When the input frequency between 140-150Hz 

5) When the input frequencies> 150Hz

1) Compressor is not running 

2) Compressor 1600rpm 

3) Adjusting the frequency of operation of the compressor corresponding to the rotational speed of the corresponding 

4) Compressor 4200rpm 

5) Compressor is not running 

 

Controller mode

5V square wave or sine wave signal control speed 

Speed ​​control accuracy

≤1% 

Standby power consumption

≤1.5W